Traffic Management Center to ITS Roadway Equipment: roadway dynamic signage data
Flow Description
Information used to initialize, configure, and control dynamic message signs. This flow can provide message content and delivery attributes, local message store maintenance requests, control mode commands, status queries, and all other commands and associated parameters that support remote management of these devices.
|
Solutions
![]() ![]() ![]() ![]() ![]() ![]() ![]() Solution Description
This solution is used within the U.S. It combines standards associated with US: NTCIP Message Sign with those for I-F: OMG DDS RPC. The US: NTCIP Message Sign standards include upper-layer standards required to implement centre-to-field message sign communications. The I-F: OMG DDS RPC standards include lower-layer standards that support secure remote procedure calls between a field device and another field device or a centre over a field communication link
|
Triple Solution Gap
|
ITS Info
NTCIP 1203
![]() |
Click gap icons for more info.
|
||
Mgmt
NTCIP 1201
![]() OMG DDS ![]() |
Facility
![]() ![]() OMG DDS
![]() OMG DDS-RPC ![]() OMG DDSI-RTPS ![]() |
Security
![]() OMG DDS-Security
![]() |
|
TransNet
|
|||